Setting the logging level - BlueCat Integrity - 26.1.0

Address Manager Administration Guide

ft:locale
en-US
Product name
BlueCat Integrity
Version
26.1.0

How to set the logging levels.

To set the logging level for server.log and zonetransfers.log:

  1. Select the Settings tab in the sidebar.
  2. Under System settings, select Log level settings.
  3. Set the Address Manager, RESTv2 API, Zone import, Reconciliation service, Discovery engine, SNMP client, and Monitoring service log levels using the following parameters:
    • Off—all logging is turned off.
    • Fatal—severe errors that caused the application or a service to stop.
    • Error—errors that occurred, but didn't stop the application or service.
    • Warn—conditions that may cause an error or that are unexpected.
    • Info—general information on normal system events.
    • Debug—detailed information on system events
    • Trace—highly detailed information on system events.
    • All—all logging is turned on.
  4. Select Update log level settings.
Note: A limitation exists in current Address Manager versions where setting the Address Manager log level to “Debug” will revert back to the default “Warn” level after several minutes of activity in other areas of the Address Manager user interface.