| Specification | Description |
|---|---|
| Base | OEM PowerEdge R7625 XL Server |
| Chassis | 3.5" Chassis with up to 12 SAS3/SATA Drives with 2x2.5" Rear, LP Adapter PERC 12 |
| Motherboard | OEM PowerEdge R7625 XL Motherboard |
| Processor | (2) AMD Epyc 9354 Processors 3.25 GHz 32C/64T |
| Memory | (16) 64 GB RDIMM, 4800 MT/s Dual Rank |
| RAID/Internal Storage Controllers | PERC H965i Adapter Low Profile, 8 GB NV Cache |
| Hard Drive |
(12) 20 TB Hard Drive SAS 12 Gbps 7.2K 512e 3.5 in Hot-Plug, AG Drive (2) 600 GB Hard Drive SAS ISE 12 Gbps 10k 512n 2.5in Flex Bay |
| Network Adapters |
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 Broadcom 5720 Dual Port 1GbE LOM |
| Fans | Very High Performance Fan x6 |
| Power Supply | Dual, Hot-plug, Redundant Power Supply (1+1), 2400W |
| Power Cords | C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America |
| PCIe Riser |
Riser Config 7
|
| Embedded Systems Management | iDRAC9, Enterprise |
| Quick Sync | None |
| Rack Rails | ReadyRails Sliding Rails Without Cable Management Arm |
PSU Specifications:
|
|
| Temperature Specifications A2: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) |
| Temperature Specifications A3: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) |
5–40°C (41–104°F) with no direct sunlight on the equipment Excursion Limited Operation
|
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) |
| Temperature Specifications A4: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) |
5–45°C (41–113°F) with no direct sunlight on the equipment Excursion Limited Operation
|
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Relative Humidity Specifications: | |
| Storage | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point. Non- condensing at all times. |
| Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
| Maximum Vibration Specifications: | |
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum Shock Pulse Specifications: | |
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms. |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms. |