LiveWire Core 1200 Technical Specifications - LiveWire

LiveWire Core 1200 Quick Start Guide

ft:locale
en-US
Product name
LiveWire
Specification Description
Base OEM PowerEdge R6525 Server
Chassis 3.5" Chassis with up to 4 Hot Plug Hard Drives
Motherboard PowerEdge R6525 Motherboard
Processor AMD 7313 3.0GHz,16C/32T (1)
Memory 64 GB 3200MT/s, Dual Rank (4x16)
RAID/Internal Storage Controllers PERC H745 Controller, Front
Hard Drive BOSS-S2 controller card + with 2 M.2 240GB (RAID 1)

8TB 7.2K RPM SAS ISE 12Gbps 512e 3.5in Hard Drive (4)

Network Adapters 2 x 1Gb Onboard LOM

Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0

Fans Standard Fan x6
Power Supply Dual, Hot Plug, Redundant Power Supply (1+1), 800W
Power Cords C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America
PCIe Riser Riser Config 1, 1 x 16 FH
Embedded Systems Management iDRAC9, Enterprise
Quick Sync None
Rack Rails ReadyRails Sliding Rails Without Cable Management Arm
PSU Specifications:

PSU

Class

Heat Dissipation (Maximum)

Frequency

Voltage

Current

8OO W Mixed Mode

Platinum

3000 BTU/hr

50/60 Hz

100–240 V AC, autoranging

9.2 - 4.7 A

Temperature Specifications A2:  
Allowable continuous operations  
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all times) 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Temperature Specifications A3:  
Allowable continuous operations  
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Temperature Specifications A4:  
Allowable continuous operations  
Temperature range for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all times) 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Temperature Specifications Shared Requirements Across All Categories:  
Allowable continuous operations  
Maximum temperature gradient (applies to both operation and non-operation) 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
Note: * - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
Non-operational temperature limits -40 to 65°C (-40 to 149°F)
Non-operational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,048 meters (10,000 feet)
Maximum Vibration Specifications:  
Operating 0.21 Grms at 5 Hz to 500 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum Shock Pulse Specifications:  
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms.