| Specification | Description |
| Base | OEM PowerEdge R6615 Server |
| Chassis | 2.5" Chassis with up to 10 Hot Plug Hard Drives |
| Motherboard | PowerEdge R6615 Motherboard |
| Processor | AMD 9254 2.9GHz 24C/48T (1) |
| Memory | 32GB RDIMM, 5600MT/s, Dual Rank (4) |
| RAID/Internal Storage Controllers | PERC H755 SAS, Front |
| Hard Drive | BOSS-N1 controller card + with 2 M.2 960GB (RAID 1)2.4TB Hard Drive SAS ISE 12Gbps 10K 512e (10) |
| Network Adapters | Broadcom 5720 Dual Port 1GbE LOMBroadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 |
| Fans | Very High Performance Fan x4 |
| Power Supply | Dual, Hot Plug, Redundant Power Supply (1+1), 1100W |
| Power Cords | C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America |
| PCIe Riser | Riser Config 3, 2 x 16 FH |
| Embedded Systems Management | iDRAC9, Enterprise |
| Quick Sync | None |
| Rack Rails | ReadyRails Sliding Rails Without Cable Management Arm |
| PSU Specifications: PSU Class Heat Dissipation (Maximum) Frequency Voltage Current |
1100W Mixed Mode Titanium 4100 BTU/hr 50/60 Hz 100-240 V AC, autoranging 12 - 6.3 A |
| Temperature Specifications ASHRAE A2: | |
| Allowable continuous operations | |
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 10 to 35°C (50 to 95°F) with no direct sunlight on the platform |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) |
| Temperature Specifications ASHRAE A3: | |
| Allowable continuous operations | |
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5 to 40°C (41 to 104°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) |
| Temperature Specifications ASHRAE A4: | |
| Allowable continuous operations | |
| Temperature range for altitudes <= 900 m (<= 2953 ft) | 5 to 45°C (41 to 113°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Common Environmental Specifications: | |
| Maximum temperature gradient (applies to both operation and non-operation) | 20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change. |
| Non-operational temperature limits | -40 to 65°C (-40 to 149°F) |
| Non-operational humidity limits | 5% to 95% RH with 27°C (80.6°F) maximum dew point |
| Maximum non-operational altitude | 12,000 meters (39,370 feet) |
| Maximum operational altitude | 3,050 meters (10,006 feet) |
| Maximum Vibration Specifications: | |
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum Shock Pulse Specifications: | |
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms |