| Specification | Description |
|---|---|
| Base | OEM Dell PowerEdge R7615 Server |
| Chassis | Chassis with up to 12 x 3.5" HDDs |
| Motherboard | OEM PowerEdge R7615 Motherboard |
| Processor | AMD EPYC 9354P 3.25 GHz, 32C/64T |
| Memory | 256 GB or RAM32GB RDIMM, 4800MT/s, Dual Rank (8) |
| RAID/Internal Storage Controllers | PERC H755 Adapter, Low Profile |
| Hard Drive | 960 GB BOSS M.2 Drives (2) 20 TB Hard Drive SAS 12 Gbps 7.2 K 512e 3.5 in Hot-Plug (12) |
| Network Adapters | Broadcom 5720 Dual Port 1Gbe LOM Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0 |
| Fans | Performance Fans (6) |
| Power Supply | Dual, Hot-Plug, Power Supply, 2400W MM (100-240 Vac), Redundant (1+1) |
| Power Cords | C13, 3 M, 125 V, 15 A (2) |
| PCIe Riser | Riser Config 3 - 2 x 16 FH (Gen5) - 2 x 8 FH - 2 x 16 LP, Half Length |
| Embedded Systems Management | iDRAC9, Enterprise |
| Quick Sync | None |
| Rack Rails | ReadyRails Sliding Rails Without Cable Management Arm |
| PSU Specifications: PSU Class Heat Dissipation (Maximum) Frequency Voltage High Line 200 V 240 V Low Line 100-140 V Current |
2400 W mixed mode Platinum 9000 50/60 2400 W 1400 N/A N/A |
| Temperature Specifications ASHRAE A2: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) | 10–35°C (50–95°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) |
| Temperature Specifications ASHRAE A3: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) | 5–40°C (41–104°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft) |
| Temperature Specifications ASHRAE A4: | |
| Allowable continuous operations | |
| Temperature range for altitudes < = 900 m (< = 2953 ft) | 5–45°C (41–113°F) with no direct sunlight on the equipment |
| Humidity percent range (non-condensing at all times) | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point |
| Operational altitude de-rating | Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft) |
| Relative Humidity Specifications: | |
| Operating | 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. |
| Storage | 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point. Non-condensing at all times. |
| Maximum Vibration Specifications: | |
| Operating | 0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations) |
| Storage | 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Maximum Shock Pulse Specifications: | |
| Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms |
| Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms |